Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1978 1
1980 1
1989 2
1990 1
1996 1
1997 3
1998 1
1999 2
2000 1
2001 3
2004 1
2005 1
2006 1
2009 3
2010 2
2011 3
2013 3
2014 2
2015 3
2016 3
2017 3
2018 3
2019 3
2021 5
2022 5
2023 5
2024 1

Text availability

Article attribute

Article type

Publication date

Search Results

53 results

Results by year

Filters applied: . Clear all
Page 1
Patients with lesions to the intraparietal cortex show greater proprioceptive realignment after prism adaptation: Evidence from open-loop pointing and manual straight ahead.
Bultitude JH, Hollifield M, Rafal RD. Bultitude JH, et al. Neuropsychologia. 2021 Jul 30;158:107913. doi: 10.1016/j.neuropsychologia.2021.107913. Epub 2021 Jun 15. Neuropsychologia. 2021. PMID: 34139246
Common ways to measure adaptation after-effect are to ask a person to point straight ahead with their eyes closed ("manual straight ahead", MSA), or to a seen target using their unseen hand ("open-loop pointing", OLP). ...After-effects were measured with OLP …
Common ways to measure adaptation after-effect are to ask a person to point straight ahead with their eyes closed ("manual straight a …
Manual Closed-Loop Insulin Delivery Using a Saddle Point Model Predictive Control Algorithm: Results of a Crossover Randomized Overnight Study.
Guilhem I, Penet M, Paillard A, Carpentier M, Esvant A, Lefebvre MA, Poirier JY. Guilhem I, et al. J Diabetes Sci Technol. 2017 Sep;11(5):1007-1014. doi: 10.1177/1932296817717503. Epub 2017 Jul 5. J Diabetes Sci Technol. 2017. PMID: 28677416 Free PMC article. Clinical Trial.
METHOD: In this randomized crossover study, 10 adult patients (mean hemoglobin A1c 7.35 1.04%) were assigned to be treated overnight by open loop using sensor-augmented pump therapy (open-loop SAP) or manual closed-loop delivery. ...RESULTS: Tim …
METHOD: In this randomized crossover study, 10 adult patients (mean hemoglobin A1c 7.35 1.04%) were assigned to be treated overnight by o
Open-loop glucose control: Automatic IOB-based super-bolus feature for commercial insulin pumps.
Rosales N, De Battista H, Vehí J, Garelli F. Rosales N, et al. Comput Methods Programs Biomed. 2018 Jun;159:145-158. doi: 10.1016/j.cmpb.2018.03.007. Epub 2018 Mar 9. Comput Methods Programs Biomed. 2018. PMID: 29650309
BACKGROUND AND OBJECTIVE: Although there has been significant progress towards closed-loop type 1 diabetes mellitus (T1DM) treatments, most diabetic patients still treat this metabolic disorder in an open-loop manner, based on insulin pump therapy (basal and bolus i …
BACKGROUND AND OBJECTIVE: Although there has been significant progress towards closed-loop type 1 diabetes mellitus (T1DM) treatments, most …
Development of closed-loop modelling framework for adaptive respiratory pacemakers.
Ai W, Suresh V, Roop PS. Ai W, et al. Comput Biol Med. 2022 Feb;141:105136. doi: 10.1016/j.compbiomed.2021.105136. Epub 2021 Dec 16. Comput Biol Med. 2022. PMID: 34929465
However, commercially available respiratory pacing devices operate in an open-loop fashion, which require manual adjustment of stimulation parameters for a given patient. ...We use a pacing device model with a proportional integral (PI) controller to i …
However, commercially available respiratory pacing devices operate in an open-loop fashion, which require manual adjust …
A systematic review on functional electrical stimulation based rehabilitation systems for upper limb post-stroke recovery.
Khan MA, Fares H, Ghayvat H, Brunner IC, Puthusserypady S, Razavi B, Lansberg M, Poon A, Meador KJ. Khan MA, et al. Front Neurol. 2023 Dec 8;14:1272992. doi: 10.3389/fneur.2023.1272992. eCollection 2023. Front Neurol. 2023. PMID: 38145118 Free PMC article.
More specifically, this paper aims to review different types of FES systems, their feasibility testing, or randomized control trials (RCT) studies. METHODS: The FES systems classification is based on the involvement of patient feedback within the FES control, which …
More specifically, this paper aims to review different types of FES systems, their feasibility testing, or randomized control trials …
GoCARB in the Context of an Artificial Pancreas.
Agianniotis A, Anthimopoulos M, Daskalaki E, Drapela A, Stettler C, Diem P, Mougiakakou S. Agianniotis A, et al. J Diabetes Sci Technol. 2015 May;9(3):549-55. doi: 10.1177/1932296815583333. Epub 2015 Apr 21. J Diabetes Sci Technol. 2015. PMID: 25904142 Free PMC article.
When the GoCARB is used, the corresponding percentages are 99.7% and 99.8%. In case of open loop, the time spent in severe hypoglycemic events (<50 mg/dl) is 33.6% without the GoCARB and is reduced to 0.0% when the GoCARB is used. In case of closed loop, the corr …
When the GoCARB is used, the corresponding percentages are 99.7% and 99.8%. In case of open loop, the time spent in severe hyp …
Closed-loop control for intensive care unit sedation.
Haddad WM, Bailey JM. Haddad WM, et al. Best Pract Res Clin Anaesthesiol. 2009 Mar;23(1):95-114. doi: 10.1016/j.bpa.2008.07.007. Best Pract Res Clin Anaesthesiol. 2009. PMID: 19449619 Review.
Open-loop control (manual control) by clinical personnel can be tedious, imprecise, time-consuming, and sometimes of poor quality, depending on the skills and judgement of the clinician. ...Several closed-loop control paradigms are invest
Open-loop control (manual control) by clinical personnel can be tedious, imprecise, time-consuming, and s
The perceptual dynamics of the contrast induced speed bias.
Patricio Décima A, Fernando Barraza J, López-Moliner J. Patricio Décima A, et al. Vision Res. 2022 Feb;191:107966. doi: 10.1016/j.visres.2021.107966. Epub 2021 Nov 19. Vision Res. 2022. PMID: 34808549 Free article.
We further tested these predictions using a novel experimental paradigm that allows us to measure the dynamic perceptual difference between stimuli through a series of manual pursuit open loop tasks. Results show good agreement with our model's predictions. . …
We further tested these predictions using a novel experimental paradigm that allows us to measure the dynamic perceptual difference between …
Model-based closed-loop control of thalamic deep brain stimulation.
Tian Y, Saradhi S, Bello E, Johnson MD, D'Eleuterio G, Popovic MR, Lankarany M. Tian Y, et al. Front Netw Physiol. 2024 Apr 8;4:1356653. doi: 10.3389/fnetp.2024.1356653. eCollection 2024. Front Netw Physiol. 2024. PMID: 38650608 Free PMC article.
Manual (open-loop) DBS programming solely based on clinical observations relies on neurologists' expertise and patients' experience. Continuous stimulation in open-loop DBS may decrease battery life and cause side effects. On the contrary, a clo
Manual (open-loop) DBS programming solely based on clinical observations relies on neurologists' expertise and patients
Dynamics of the Disparity Vergence Fusion Sustain Component.
Semmlow JL, Yaramothu C, Alvarez TL. Semmlow JL, et al. J Eye Mov Res. 2019 Oct 3;12(4):10.16910/jemr.12.4.11. doi: 10.16910/jemr.12.4.11. Epub 2019 Dec 4. J Eye Mov Res. 2019. PMID: 32318253 Free PMC article.
The initial component has been well-studied and is thought to be controlled by an open-loop mechanism. Less is known about the slow, or fusion sustaining component except that it must be feedback controlled to achieve the positional precision of sustained fusion. Gi …
The initial component has been well-studied and is thought to be controlled by an open-loop mechanism. Less is known about the …
53 results